The tables below show technical scopes that may be assessed in training and consultancy work. They do not declare an accreditation scope held by AKREKAL; the methods, ranges and conditions applicable to your organisation are verified separately.
Areas of Expertise Measured Quantity / Instruments Calibrated Measurement Range Measurement Conditions Calibration and Measurement Capability (k=2) Remarks / Calibration Method
Calibration/Ionising Radiation and Radioactivity/Dosimetric Quantities Therapy-Level Dosimeters:

Ionisation chamber

Electrometer

Air Kerma (Nk)(100 cm)

Dose: 2.91 mGy

Dose Rate: 10.48 Gy.h-1

Co-60 source

34.52 TBq

1,10% Substitution method;

IAEA Technical Reports Series No:277-381 protocols are applied.

Performed at the Customer’s Site, in the Laboratory, or at a Temporary or Mobile Facility.

Calibration/Ionising Radiation and Radioactivity/Dosimetric Quantities Therapy-Level Dosimeters:

Ionisation chamber

Electrometer

Absorbed in Water

Dose:(NDW) (100 cm)

Dose: 2.87 mGy

Dose Rate: 10.33 Gy.h-1

Co-60 source

34.52 TBq

May.18

1,00% Substitution method;

The IAEA Technical Reports Series No:398 protocol is applied.

Performed at the Customer’s Site, in the Laboratory, or at a Temporary or Mobile Facility.

Calibration/Mechanical Quantities/Hardness Hardness Reference Block

Rockwell

Hardness Reference Block

Brinell Hardness Reference Block

Vickers Hardness Reference Block

 

HRA

–  

0,40 HRA

 

Calibration is performed in accordance with ISO 6508-3 and ASTM E18.

Performed at the Customer’s Site, in the Laboratory, or at a Temporary or Mobile Facility.

In the laboratory

At temporary or mobile facilities

Calibration/Mechanical Quantities/Hardness Hardness Tester

Rockwell Hardness Tester

Brinell Hardness Tester

Vickers Hardness Tester

Portable (Handheld) Hardness Tester

Shore Hardness Tester

IRHD Hardness Tester

 

30 < HRC < 64

 

Indirect Calibration Using Hardness Reference Blocks

 

1,8 HRC

 

Calibration is performed using a procedure prepared in accordance with DIN 50156-2.

Performed at the Customer’s Site, in the Laboratory, or at a Temporary or Mobile Facility.

Calibration/Mechanical Quantities/Hardness Hardness Indenter

Rockwell Spheroconical Diamond Indenter

Vickers Pyramidal Diamond Indenter

Brinell and Rockwell Ball Indenters

Shore, IRHD and Other Indenters

 

0 ° < α < 180 °

0 ° ≤ α ≤ 90 °

0,2 mm ≤ R ≤ 0,25 mm

0 mm ≤ S ≤ 0,002 mm

 

Angle

Axial deviation angle

Radius

Linearity

 

0,01°

0,01°

0 5 μm

1 μm

 

Calibration using a procedure prepared in accordance with ASTM E 18 and ISO 6508-2.

Performed at the Customer’s Site, in the Laboratory, or at a Temporary or Mobile Facility.

Calibration/Mechanical Quantities/Hardness Hardness Tester

Calibration of Optical Indentation Measuring Equipment in Hardness Testing Machines

L ≤ 20 mm TS EN ISO 6506-2

TS EN ISO 6507-2

1,5x 10⁻³ · L (μm), provided it is not less than 0,5 μm L: Measured value

Measurement Principle: Using a Stage Micrometer

Performed at the Customer’s Site, in the Laboratory, or at a Temporary or Mobile Facility.

Calibration/Mechanical Quantities/Hardness Hardness Tester

Indentation Depth Calibration in Hardness Testing Machines

0mm ≤ L ≤ 10mm TS EN ISO 6506-2

TS EN ISO 6507-2

1,5x 10⁻³ · L (μm), provided it is not less than 0,5 μm L: Measured value

Measurement Principle: Using a Stage Micrometer

Performed at the Customer’s Site, in the Laboratory, or at a Temporary or Mobile Facility.

Calibration/Temperature/Fixed Points Contact Temperature Fixed-Point Cells

Primary-Level Fixed-Point Cell

Secondary-Level Fixed-Point Cell

500K Ambient Temperature 5 mK Comparison of fixed points

Performed at the Customer’s Site, in the Laboratory, or at a Temporary or Mobile Facility.

In the laboratory

Calibration/Temperature/Resistance Thermometers Standard Platinum Resistance Thermometers

Capsule-Type SPRT

Long-Stem SPRT (including HTSPRT)

-100 °C ≤ T ≤ 100 °C In a Liquid Bath

In a Block Calibrator

3 °C Laboratory and on-site calibration by the comparison method

T: Measured Temperature [°C]

Performed at the Customer’s Site, in the Laboratory, or at a Temporary or Mobile Facility.

Calibration/Temperature/Resistance Thermometers Resistance Thermometers

Platinum Resistance Thermometers (PRT)

Industrial Platinum Resistance Thermometers (PRT)

Thermistor

-45 °C ≤ T ≤ 300 °C In a Liquid Bath

In a Block Calibrator

0,09 °C Laboratory and on-site calibration by the comparison method

T: Measured Temperature [°C]

Performed at the Customer’s Site, in the Laboratory, or at a Temporary or Mobile Facility.

Calibration/Temperature/Thermocouples Thermocouples

Platinum-Based Reference Thermocouples

R

S

B

Platinum/Palladium (Pt/Pd)

Gold/Platinum (Au/Pt)

-100°C ≤ T ≤ 100°C In a Liquid Bath

In a Block Calibrator

5,8 °C Laboratory and on-site calibration by the comparison method

T: Measured Temperature [°C]

Performed at the Customer’s Site, in the Laboratory, or at a Temporary or Mobile Facility.

Calibration/Temperature/Thermocouples Thermocouples

Industrial Thermocouples

T

E

K

N

J

U

L

-100°C ≤ T ≤ 100°C In a Liquid Bath

In a Block Calibrator

5,8 °C Laboratory and on-site calibration by the comparison method

T: Measured Temperature [°C]

Performed at the Customer’s Site, in the Laboratory, or at a Temporary or Mobile Facility.

Calibration/Temperature/Liquid-in-Glass Thermometers Liquid-in-Glass Thermometers 0 °C Ice Point 1,23 °C Laboratory Calibration by the Comparison Method

T: Temperature 0,05 °C

Performed at the Customer’s Site, in the Laboratory, or at a Temporary or Mobile Facility.

Calibration/Temperature/Resistance Thermometers; Calibration/Temperature/Thermocouples Temperature Measuring Instruments with Displays

(with thermistor, resistance or thermocouple sensor)

-10°C < T < 10 °C In a Liquid Bath 1,23 °C Laboratory and On-Site Calibration

T: Temperature 0,5 °C

Performed at the Customer’s Site, in the Laboratory, or at a Temporary or Mobile Facility.

Calibration/Temperature/Thermocouples; Calibration/Temperature/Resistance Thermometers Other Thermometers

Surface Temperature Thermometers

Air Sensors

-10°C < T < 10 °C On a surface temperature plate 1,23 °C Laboratory and On-Site Calibration

T: Temperature

Performed at the Customer’s Site, in the Laboratory, or at a Temporary or Mobile Facility.

Calibration/Temperature/Resistance Thermometers; Calibration/Temperature/Thermocouples Other Thermometers

Air Sensors

-10°C < T < 10 °C On a surface temperature plate 1,23 °C Laboratory and On-Site Calibration

T: Temperature

Performed at the Customer’s Site, in the Laboratory, or at a Temporary or Mobile Facility.

Calibration/Temperature/Thermocouples Other Measurement Services

Compensating Cables for Cold Junctions

-10°C < T < 10 °C Cold Junction On/Off 1,23 °C Laboratory and On-Site Calibration

T: Temperature

Performed at the Customer’s Site, in the Laboratory, or at a Temporary or Mobile Facility.

Calibration/Temperature/Thermocouples Other Measurement Services

Wire Melting-Point Cable for Thermocouples

-10°C < T < 10 °C Cold Junction On/Off 1,23 °C Laboratory and On-Site Calibration

T: Temperature

Performed at the Customer’s Site, in the Laboratory, or at a Temporary or Mobile Facility.

Calibration/Temperature/Temperature Indicators and Calibrators Temperature Indicators and Calibrators

Temperature Indicator

Cold Junction ON

Cold Junction OFF

-10°C < T < 10 °C Type J

Type T

1,23 °C Calibration procedure prepared in accordance with EURAMET cg-11

On site or in the laboratory

Electrical simulation method

T: Temperature

Performed at the Customer’s Site, in the Laboratory, or at a Temporary or Mobile Facility.

Calibration/Temperature/Temperature Indicators and Calibrators Temperature Indicators and Calibrators

Temperature Calibrator

Cold Junction ON

Cold Junction OFF

-10°C < T < 10 °C Type J

Type T

1,23 °C Calibration procedure prepared in accordance with EURAMET cg-11

On site or in the laboratory

Electrical simulation method

T: Temperature

Performed at the Customer’s Site, in the Laboratory, or at a Temporary or Mobile Facility.

Calibration/Temperature/Temperature Sources Controlled Volumes (Temperature Distribution)

Oven

Incubator

Cold Room (deep freezer, etc.)

Climatic Chamber

Steriliser (Autoclave)

Liquid Bath

Muffle Furnace

-10°C < T < 10 °C 1,23 °C According to the Euramet cg-20 and DKD-R 5-7 guidance documents

On-site calibration using a portable calibration system

T: Temperature

Performed at the Customer’s Site, in the Laboratory, or at a Temporary or Mobile Facility.

Calibration/Temperature/Temperature Sources Other Measurement Services

Dry-Block Calibrators

-10°C < T < 10 °C Using a Reference Thermocouple 1,23 °C Calibration procedure prepared in accordance with Euramet cg-13

using the comparison calibration method

T: Temperature

Performed at the Customer’s Site, in the Laboratory, or at a Temporary or Mobile Facility.

Calibration/Temperature/Radiation Thermometers Radiation Temperature Fixed-Point Cells

Primary-Level Fixed-Point Cell

Secondary-Level Fixed-Point Cell

-10°C < T < 10 °C 1,23 °C  

T: Temperature

Performed at the Customer’s Site, in the Laboratory, or at a Temporary or Mobile Facility.

Calibration/Temperature/Radiation Thermometers Reference Radiation Thermometers -10°C < T < 10 °C 1,23 °C  

T: Temperature

Performed at the Customer’s Site, in the Laboratory, or at a Temporary or Mobile Facility.

Calibration/Temperature/Radiation Thermometers Industrial Radiation Thermometers

Pyrometer

Thermal Camera

IR Thermometer

IR Ear Thermometer

-10°C < T < 10 °C Using an IR Calibrator 1,23 °C Laboratory and on-site calibration

T: Temperature

Performed at the Customer’s Site, in the Laboratory, or at a Temporary or Mobile Facility.

Calibration/Temperature/Radiation Thermometers Variable-Temperature Blackbody Sources

Blackbody

IR Calibrator

-10°C < T < 10 °C Wavelength: 10µm 1,23 °C Comparison Measurement

T: Temperature

Performed at the Customer’s Site, in the Laboratory, or at a Temporary or Mobile Facility.

Calibration/Temperature/Radiation Thermometers Ribbon Lamps

Vacuum Lamp

Gas Lamp

-10°C < T < 10 °C 1,23 °C T: Temperature

Performed at the Customer’s Site, in the Laboratory, or at a Temporary or Mobile Facility.

Calibration/Temperature/Humidity Hygrometers

Dew-Point Temperature Meter

Hygrometer

Relative Humidity Meter (capacitive, resistive, thermographic, mechanical, wet/dry bulb)

Moisture Meter

-10°C < T < 10 °C Digital and Analogue 1,23 %RH RH: Measured value

T: Temperature

Performed at the Customer’s Site, in the Laboratory, or at a Temporary or Mobile Facility.

Calibration/Temperature/Humidity Dynamic Sources

Dew-Point Source

Relative Humidity Source

Flow Mixing

-10°C < T < 10 °C % 1,23 RH RH: Measured Value

T: Temperature

Calibration in a Humidity Chamber

Analogue/Digital Relative Humidity Meter

Performed at the Customer’s Site, in the Laboratory, or at a Temporary or Mobile Facility.

Calibration/Temperature/Humidity Static Sources

Salt Solution

Saturated Salt Solution

Unsaturated Salt Solution

43,2% rh % 1,23 RH RH: Measured Value

T: Temperature

Performed at the Customer’s Site, in the Laboratory, or at a Temporary or Mobile Facility.

Calibration/Temperature/Humidity Static Sources

Reference Gases

43,2% rh % 1,23 RH RH: Measured Value

T: Temperature

Performed at the Customer’s Site, in the Laboratory, or at a Temporary or Mobile Facility.

Calibration/Temperature/Humidity Controlled Volumes (Relative Humidity Distribution)

Climatic Chamber

Relative Humidity Source

Steriliser (Autoclave)

0 °C < T ≤ 10 °C Single Point 1,5 °C Using the Comparison Method

T: Temperature

Performed at the Customer’s Site, in the Laboratory, or at a Temporary or Mobile Facility.

Calibration/Mechanical Quantities/Weighing Instruments Non-Automatic Weighing Instruments

Balance

1 mg < m < 1 kg Using E2 class weights 2 · 10-6 m : Balance capacity (g)

Calibration procedure prepared in accordance with EURAMET/cg-18.

Performed at the Customer’s Site, in the Laboratory, or at a Temporary or Mobile Facility.

Calibration/Mechanical Quantities/Weighing Instruments Non-automatic weighing instruments

Balance

1 mg < m < 40 kg Using F1 class weights 1,1·10-5  

m : Balance capacity (g)

Calibration procedure prepared in accordance with EURAMET/cg-18.

Performed at the Customer’s Site, in the Laboratory, or at a Temporary or Mobile Facility.

Calibration/Mechanical Quantities/Weighing Instruments Non-automatic weighing instruments

Balance

5 kg < m < 1000 kg Using M1 class weights 1,6·10-4  

m : Balance capacity (g)

Calibration procedure prepared in accordance with EURAMET/cg-18.

Performed at the Customer’s Site, in the Laboratory, or at a Temporary or Mobile Facility.

Calibration/Mechanical Quantities/Weighing Instruments Non-automatic weighing instruments

Balance

1000 kg < m < 2000 kg Using substitution weights 3·10-4  

m : Balance capacity

Calibration procedure prepared in accordance with EURAMET/cg-18.

Performed at the Customer’s Site, in the Laboratory, or at a Temporary or Mobile Facility.

Calibration/Mechanical Quantities/Materials Testing Machines Materials Testing Machines

Tensile / Compression Testing Machine

Compression Testing Machine

Tensile Testing Machine

Concrete Testing Machine

Notched Impact Testing Machine

Extensometer

200 N < F < 100 kN In tension using a class 0,5 load cell 0,16% F: Applied force (N)

Performed at the Customer’s Site, in the Laboratory, or at a Temporary or Mobile Facility.

Calibration/Mechanical Quantities/Materials Testing Machines Compression Testing Machine 200 N < F < 100 kN In tension using a class 0,5 load cell. 0,16% F: Applied force (N)

Calibration procedure prepared in accordance with TS EN ISO 7500-1, ISO 7500-1 and ASTM E4

Performed at the Customer’s Site, in the Laboratory, or at a Temporary or Mobile Facility.

Calibration/Mechanical Quantities/Materials Testing Machines Tensile/Compression Testing Machine 200 N < F < 100 kN In tension using a class 0,5 load cell. 0,16% F: Applied force (N)

Calibration procedure prepared in accordance with TS EN ISO 7500-1, ISO 7500-1 and ASTM E4

Performed at the Customer’s Site, in the Laboratory, or at a Temporary or Mobile Facility.

Calibration/Mechanical Quantities/Materials Testing Machines Extensometer L ≤ 100 mm Using a probe ( 0,5 + 7 · L) μm L : Measured Value (m)

Calibration procedure prepared in accordance with TS EN ISO 9513 and ASTM E83

Performed at the Customer’s Site, in the Laboratory, or at a Temporary or Mobile Facility.

Calibration/Mechanical Quantities/Materials Testing Machines Notched Impact Tester

Izod Impact Tester

0,5 J < Ap < 750 J Tension using a Class 0.5 Load Cell Force: %0,16

Pendulum Length: 0,5 mm

Angle: 0,1ᵒ

Ap : Potential energy (Joule)

Calibration procedure prepared in accordance with TS EN ISO 148-2, ASTM E23 and TS EN ISO 13802.

Measurement uncertainty is calculated for the following parameters:

1-Centre of percussion

2-Potential energy

3-Indicator deviation

Performed at the Customer’s Site, in the Laboratory, or at a Temporary or Mobile Facility.

Calibration/Mechanical Quantities/Materials Testing Machines Concrete Testing Presses 200 N < F < 3 MN Using a class 1 load cell 0,32% F: Applied force (N)

Calibration procedure prepared in accordance with TS EN 12390-4

Performed at the Customer’s Site, in the Laboratory, or at a Temporary or Mobile Facility.

Calibration/Mechanical Quantities/Torque Torque Measuring Instruments

Torque Calibration Machine

Torque Transducer

Reference Torque Wrench

Torque Hand Tool Calibration Rig

Torque Hand Tools

Torque Multiplier

100 N·m < M < 2000 N·m Using a Class 0,5 load cell

(Clockwise and anticlockwise)

% 1,0 M : Measured Torque (N·m)

Calibration procedure prepared in accordance with ISO 6789-2.

Performed at the Customer’s Site, in the Laboratory, or at a Temporary or Mobile Facility.

Calibration/Mechanical Quantities/Vacuum Quantities Vacuum Gauge Calibration

Capacitance Diaphragm Vacuum Gauge

Spinning Rotor Vacuum Gauge (SRG)

Hot and Cold Cathode Vacuum Gauges

Pirani, Thermal Conductivity and Thermocouple Vacuum Gauges

 Performed at the Customer’s Site, in the Laboratory, or at a Temporary or Mobile Facility.